Reference Number NIA_NGGT0010
Title Backup DC Drive Electronic Starter
Status Completed
Energy Categories Fossil Fuels: Oil Gas and Coal(Oil and Gas, Refining, transport and storage of oil and gas) 100%;
Research Types Applied Research and Development 100%
Science and Technology Fields ENGINEERING AND TECHNOLOGY (Electrical and Electronic Engineering) 100%
UKERC Cross Cutting Characterisation Not Cross-cutting 100%
Principal Investigator Project Contact
No email address given
National Grid Gas Transmission
Award Type Network Innovation Allowance
Funding Source Ofgem
Start Date 01 June 2012
End Date 31 March 2014
Duration 22 months
Total Grant Value £115,000
Industrial Sectors Manufacturing
Region London
Programme Reliability
 
Investigators Principal Investigator Project Contact , National Grid Gas Transmission (100.000%)
Web Site http://www.smarternetworks.org/Project/NIA_NGGT0010
Objectives The objective of the project is to develop a safer and more reliable alternative to the resistance type motor starters currently installed on compressor sites.
Expected Benefits:
The project success will be a successful trial of the performance of the dc electronic starter motors on a National Grid Compressor site. A successful starter design will provide a simplified motor starter with less discrete electro-mechanical components
Abstract Most compressor station Gas Turbine units have a number of battery powered emergency back up dc motors driving the vent fans, lube pumps etc. which are started in the event of a mains power failure. Currently these motors are started from resistor type starters located within each compressor units dc motor control centre.
At a number of compressor stations these resistor starters have overheated causing damage to the control equipment and constituting a fire risk.
It is proposed to replace these with a new dc electronic motor starter. DC electronic motor starters are not available as off the shelf products for a dc battery supply and will therefore require design and development. A prototype will be designed and tested and then a working unit will be installed at Wooler compressor station for a trial followed by the installation of the remaining 2 within the unit.
Publications (none)
Final Report Backup DC drive electronic starter - Closedown Report - NIA_NGGT0010_CL_5056.pdf (PDF 49 KB)
Added to Database 07/10/16